1. 01 · site
  2. 02 · loop
  3. 03 · supply

Smoulder first.Then smoke.The panel already knows.

Cerberus PRO for buildings where a false alarm costs more than a detector. The sheet holds FC722, OP720, HI720, FDM225-RP and I/O modules — not someone else's range.

Site type · zones light up on the drawing

OP720 in the open office, FDM225-RP on escape routes, FC722 on two C-NET loops. The drawing highlights the open office.

Live loop

Floor 3 · Sirius Center

Standby

How the loop is built

Zones and scenarios first, SKUs after

  1. 01

    Detection

    OP720 reads smoke by scattered light on C-NET. HI720 goes into kitchens, steam and dust: the panel picks a fixed A2S threshold or rate-of-rise A2R.

  2. 02

    Panels

    FC722-ZA and FC722-ZZ are one Cerberus PRO platform: two loops, 252 addresses, room to grow to four. They differ by the housing language kit, not the architecture.

  3. 03

    Integration

    FDCIO222 drives HVAC, lifts and doors. FDCIO224 releases extinguishing through the VdS interface. FDCI221 and FDCI222 confirm dampers and door contacts.

Sheet

The catalog only lists what sits on the loop

Cerberus PRO from this sheet: FC722 panels, OP720 smoke, HI720 heat, the FDM225-RP call point and FDCI/FDCIO modules. No aspiration, beam detectors or sounders here.

  1. 01

    Panels

    FC722-ZA and FC722-ZZ. Two C-NET loops, up to 252 addresses, growth to four loops. Stand-alone or clustered on C-WEB/SAFEDLINK.

  2. 02

    Detectors

    OP720 is a point smoke detector on scattered light, with a short-circuit isolator. HI720 is the heat detector for rooms where a smoke chamber is useless.

  3. 03

    Call point

    FDM225-RP, type A to EN 54-11. Alarm by pressing out a plastic insert, reset with a key, no glass, isolator inside.

  4. 04

    Modules

    FDCIO222 and FDCIO224 give four relays and four inputs. FDCIO223 hangs collective lines. FDCI222, FDCIO221 and FDCI221 cover one point or four. FDCH221 is the IP65 box.

Kit for the selected site

Items that usually land on the first sheet

Full catalog
Siemens OP720 C-NET optical smoke detector

OP720

Siemens OP720 C-NET optical smoke detector

Point-type OP720 (S54310-F1-A1) watches smoke by scattered light on the C-NET loop of FS720 panels. It covers smouldering and flaming fires, sensitivity is picked at the panel, and a short-circuit isolator sits inside to EN 54-17. Order the LP720 base separately — the box holds the head and a dust cap. Pure-white ~RAL 9010 housing, IP40, or IP42 with an RS720 seal.

RUB 6,000 RUB 4,100 −32%

Siemens FDCIO222 4-in / 4-relay module

FDCIO222

Siemens FDCIO222 4-in / 4-relay module

Addressable FDCIO222 (A5Q00002369) sits on FDnet or C-NET with four dry 250 V / 4 A relays and four supervised inputs. The panel drives doors, fans, lifts and access control; the inputs report position or raise alarm. Loop-powered, LED status, EN 54-17/18. Resistors and TS35 feet are in the box.

RUB 29,000 RUB 20,850 −28%

Siemens FC722-ZA Cerberus PRO fire control panel

FC722-ZA

Siemens FC722-ZA Cerberus PRO fire control panel

Compact Cerberus PRO FC722-ZA panel (S54400-C29-A2) in Comfort housing: two C-NET loops, expandable to four, up to 252 addresses. Stand-alone or clustered on C-WEB/SAFEDLINK — 32 panels, or 64 across a fibre C-WEB/LAN fabric that meets EN 54. Auto-learns devices, keeps 2000 events and watches loops for earth faults. Batteries and option cards are ordered separately.

RUB 300,000 RUB 289,000 −4%

Siemens FC722-ZZ Cerberus PRO fire control panel

FC722-ZZ

Siemens FC722-ZZ Cerberus PRO fire control panel

FC722-ZZ (S54400-C29-A5) is the same two-loop Cerberus PRO platform as the ZA, packed for a different language kit. 252 C-NET addresses, growth to four loops, C-WEB/SAFEDLINK networking and Cerberus-Engineering-Tool. Built for hotels, workshops or as a node in a campus layout.

RUB 285,000 RUB 199,500 −30%